Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Reprod Biomed Online ; 48(3): 103643, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38262209

RESUMO

RESEARCH QUESTION: Does a commercially available quantitative beta-human chorionic gonadotrophin (BHCG) point of care testing (POCT) device improve workflow management in early pregnancy by performing comparably to gold standard laboratory methods, and is the performance of a validated pregnancy of unknown location (PUL) triage strategy maintained using POCT BHCG results? DESIGN: Women classified with a PUL between 2018 and 2021 at three early pregnancy units were included. The linear relationship of untreated whole-blood POCT and serum laboratory BHCG values was defined using coefficients and regression. Paired serial BHCG values were then incorporated into the validated M6 multinomial logistic regression model to stratify the PUL as at high risk or at low risk of clinical complications. The sensitivity and negative predictive value were assessed. The timings required for equivocal POCT and laboratory care pathways were compared. RESULTS: A total of 462 PUL were included. The discrepancy between 571 laboratory and POCT BHCG values was -5.2% (-6.2 IU/l), with a correlation coefficient of 0.96. The 133 PUL with paired 0 and 48 h BHCG values were compared using the M6 model. The sensitivity for high-risk outcomes (96.2%) and negative predictive values (98.5%) was excellent for both. Sample receipt and laboratory processing took 135 min (421 timings), compared with 12 min (91 timings) when using POCT (P < 0.0001). CONCLUSIONS: POCT BHCG values correlated well with laboratory testing measurements. The M6 model retained its performance when using POCT BHCG values. Using the model with POCT may improve workflow and patient care without compromising on effective PUL triage.


Assuntos
Gravidez Ectópica , Gravidez , Humanos , Feminino , Gonadotropina Coriônica , Gonadotropina Coriônica Humana Subunidade beta , Valor Preditivo dos Testes , Modelos Logísticos
2.
BMJ Case Rep ; 14(3)2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33649039

RESUMO

Transient osteoporosis of the hip (TOH) is a rare cause of pelvic pain in the third trimester of pregnancy and post partum. Although several cases have been reported in literature, its aetiology is poorly understood. The diagnosis is commonly missed in pregnancy, as the presenting symptoms can be vague, and the risks of radiographic imaging deter clinicians from pursuing investigation. In extreme cases, this pathology presents with neck of femur fractures, with no current guidelines on optimal management. We describe the case of a 24-year-old woman who presented with bilateral neck of femur fractures at 34 weeks gestation. Following an emergency caesarean section, operative management consisted of bilateral closed reduction and internal fixation using dynamic hip screws. Postoperative radiographs demonstrated failure of fixation on the left side, which was revised to a complex primary arthroplasty. This case demonstrates both the diagnostic and management challenges associated with TOH.


Assuntos
Fraturas do Colo Femoral , Ortopedia , Osteoporose , Complicações na Gravidez , Adulto , Cesárea , Feminino , Fraturas do Colo Femoral/diagnóstico por imagem , Fraturas do Colo Femoral/cirurgia , Fêmur , Humanos , Osteoporose/complicações , Osteoporose/diagnóstico por imagem , Gravidez , Complicações na Gravidez/diagnóstico por imagem , Complicações na Gravidez/cirurgia , Terceiro Trimestre da Gravidez , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...